C8103 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeLift up mechanism trouble (Upward movement)
Trouble codeC8103
RankB
Detection timingThe lift up upper sensor (PS2) is not unblocked after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward).
Trouble isolation
Relevant electrical parts• Lift-up motor (M5)
• Lift-up upper sensor (PS2)
• DF control board (DFCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary.
2Check the connector of M5 for proper drive coupling, and correct as necessary.
3Check the connectors between PS2-relay CN110-DFCB CN5 for proper connection, and correct as necessary.
4PS2 I/O check, sensor checkDFCB CN5-3 (ON)DF-702 10-C
5M5 operation checkDFCB CN11-4 to 7DF-702 13-C
6Replace M5 (Part# A108R70400)
7DFCB ICP13 conduction check
8Replace DFCB (Part# A3CKH00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.2 (Link to the Field Service Manual)