C7133 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7133: Toner supply motor/YM failure |
Rank | C |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Toner supply motor/YM (M4) -Base board (BASEB) |
Procedure
- Check the connector between M4-BASEB CN13E for proper connection and correct as necessary.
- Check the connector of M4 for proper drive coupling and correct as necessary.
- M4 conduction check
- Control signal: BASEB CN13E-1 to 4
- Location of electrical component: 4-C
- Replace M4. (Part# A7PUM10700)
- Replace BASEB. (Part# A93EH02007)
L.3.12.3 (Link to the Field Service Manual)