C3305 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Switchback paper cooling fanâ??s failure to turn |
Trouble code | C3305 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Switchback paper cooling fan (FM4) -Paper feed/transport drive board (PFTDB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM4-relay CN282-relay CN280-relay CN279-PFTDB CN10 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM4 operation check | PFTDB CN10-11 (LOCK) | 6-P |
4 | Replace FM4 (Part# 9J06M10000) | – | – |
5 | PFTDB ICP9 conduction check | – | – |
6 | Replace PFTDB (Part# A2X0H00202) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
- Link to the layout drawings for related parts by each trouble code (S.71. C3305)
K.3.8.5 (Link to the Field Service Manual)