C1109 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Stapler motors drive malfunction | |
Trouble code | C1109 | |
Rank | B | |
Detection timing | <When FS-533 is installed> The stapler home sensor (PS110) is not blocked even after the set period of time has elapsed after the stapler motor turned ON. | |
<When FS-534 is installed> -The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the stapler motor (M14) turned ON. -The stapler position sensor (Center) (PS24) is blocked, when the stapler motor (M14) is running. | ||
<When FS-535 is installed> The home sensor in the staple unit does not turn ON even after the set period of time has elapsed after the stapler motor (M14) turned ON, and the home sensor in the staple unit does not turn ON even after the set period of time has elapsed after the stapler motor (M14) drives to the reverse direction. | ||
Trouble isolation | Staple | |
Relevant electrical parts | <When FS-533 is installed> -Stapler home sensor (PS110) -Stapler unit -Stapler relay board (STREYB) -FS control board (FSCB) | |
<When FS-534 is installed> -Stapler home position sensor (Rear) (PS23) -Stapler unitStapler position sensor (Center) (PS24) -FS control board (FSCB) | ||
<When FS-535 is installed> -Stapler unit -Stapler motor (M14) -FS control board (FSCB) |
(2)Procedure When FS-533 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between the stapler unit-STREYB CN122 and CN123 for proper connection and correct as necessary. | – | – |
2 | Check the connector of the stapler unit for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary. | – | – |
4 | PS110 I/O check, sensor check | FSCB CN110 | FS-533 8-D to E |
5 | Replace the stapler unit (Part# A2YUPPK401) | – | – |
6 | Replace STREYB (Part# A2YUPPG700) | – | – |
7 | Replace FSCB (Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2) | – | – |
- Link to the wiring diagram (N.3.7 FS-533)
- Link to the layout drawings for related parts by each trouble code (S.24.1 FS-533)
When FS-534 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary. | – | – |
2 | Check the connector of the stapler unit for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS23-relay CN3-FSCB J11 for proper connection and correct as necessary. | – | – |
4 | Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary. | – | – |
5 | PS23 I/O check, sensor check | FSCB J11<B>-3 (ON) | FS-534 4-C |
6 | PS24 I/O check, sensor check | FSCB J11<B>-6 (ON) | FS-534 4 to 5-C |
7 | Replace the stapler unit (Part#A3EP560100) | – | – |
8 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.3.8 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.24.2 FS-534)
When FS-535 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M14-FSCB CN15 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M14 for proper drive coupling, and correct as necessary. | – | – |
3 | Replace the stapler unit (Part# A07P790100) | – | – |
4 | M14 operation check | FSCB CN15-1 to 2 | FS-535 8 to 9-D |
5 | Replace M14 (Part# A2Y1M10200) | – | – |
6 | FSCB ICP10 conduction check | – | – |
7 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.3.10 FS-535)
- Link to the layout drawings for related parts by each trouble code (S.24.3 FS-535)
K3.6.11 (Link to the Field Service Manual)