Skip to main content

C2A22 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeToner cartridge/M new release failure
Trouble codeC2A22: Toner cartridge/M new release failure
RankC
Detection timingThe status with the new cartridge is not cleared after the new toner cartridge is set.
Trouble isolation–
Relevant electrical parts-Toner cartridge/C,M,Y,K
-Extension control board (EXCB)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Clean the connection between the toner cartridge and the machine if dirty.––
2Check the connector between toner cartridge-relay CN79-EXCB CN4 for proper connection and correct as necessary.

3Reinstall the toner cartridge––
4Check the harness for proper connection and correct as necessary.––
5Check the connector between EXCB CN2-PRCB CN11 for proper connection and correct as necessary.––
6Replace the toner cartridge (Part# A33K332)––
7Replace PRCB (C554 Part# A2XKH00104 / C454 A4FJH00104)––

K3.7.13 (Link to the Field Service Manual)