C5355 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Toner bottle cooling fans failure to turn | |
Trouble code | C5355 | |
Rank | B | |
Detection timing | <bizhub C454> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary. | |
Trouble isolation | – | |
Relevant electrical parts | -Toner bottle cooling fan (FM4) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM4-relay CN111-PRCB CN36 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM4 operation check | PRCB CN36-2 (REM)PRCB CN36-3 (LOCK) | 26-C |
4 | Replace FM4 (Part# A0EDM10500) | – | – |
5 | PRCB ICP18 conduction check | – | – |
6 | Replace PRCB (Part# A4FJH00104) | – | – |
- Link to the wiring diagram (N.1. bizhub C554/C454)
- Link to the layout drawings for related parts by each trouble code (S.100. C5355)
K3.10.6 (Link to the Field Service Manual)