C1141 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Paddle motors drive malfunction | |
Trouble code | C1141 | |
Rank | B | |
Detection timing | <When FS-534 is installed> The upper paddle homeposition detection sensor (PS14) is not blocked or unblocked even after the set period of time has elapsed while the FNS paddle motor (M5) is turning. | |
Trouble isolation | Staple | |
Relevant electrical parts | -FNS paddle motor (M5) -Upper paddle home position detection sensor (PS14) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M5-FSCB J4 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M5 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS14-FSCB J4 for proper connection, and correct as necessary. | – | – |
4 | PS14 I/O check, sensor check | FSCB J4<B>-7 (ON) | FS-534 13-C |
5 | M5 operation check | FSCB J4<A>-5 to 8 | FS-534 12-C to D |
6 | Replace M5 (Part# A3EPPP5500) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.26. C1141)
K3.6.14 (Link to the Field Service Manual)