C0351 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0351: Paper cooling fan/in failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Paper cooling fan/in (FM12) -Process drive board (PDB) |
Procedure
- Check the connector between FM12-relay CN325-PDB CN10 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM12 load check
- Check code: 42
- Multi code: 18, 19
- Control signal: PDB CN10-1 (DRIVE), PDB CN10-3 (LOCK)
- Location of electrical component: 18-X
- Replace FM12. (Part# 9313100072)
- PDB F4 conduction check
- Replace PDB. (Part# A8JEH00400)