C265B (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C265B: Main backup media 2 access error |
Rank | C |
Trouble detection condition | -The re-written data, which has been read out, checked and founded as error, is read out again and found as error. -The error was found when reading out the counter value. -The main body detects that the back up board is not mounted. |
Trouble isolation | – |
Relevant electrical parts | -Back up board/2 (ERB/2) -MFP board (MFPB) |
Procedure
- Check the connector between ERB/1-MFPB CN11E for proper connection and correct as necessary.
- Check the connector between ERB/2-relay CN6-MFPB CN11E for proper connection and correct as necessary.
- Replace MFPB. (Part# A8JEH02002)
- Replace ERB. (ERB/2 Part# A7AHH00C00)
- If the above actions do not solve the problem, contact KM.
L.3.9.19 (Link to the Field Service Manual)