C3201 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C3201: Fusing motor failure to turn | 
| Rank | B | 
| Trouble detection condition | The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Fusing motor (M30) -MFP board (MFPB)  | 
Procedure
- Check the connector between M30-MFPB CN28E for proper connection and correct as necessary.
 - Check the loading status of the fusing unit drive, and correct the error as necessary.
 - M30 load check
- Check code: 45
 - Multi code: 1, 2, 3, 4, 5, 6
 - Control signal: MFPB CN28E-1 (DC24V), MFPB CN28E-4 (REM), MFPB CN28E-7 (LOCK)
 - Location of electrical component: 7-K
 
 - Replace M30. (Part# A796M10200)
 - MFPB F16E conduction check
 - Replace MFPB. (Part# A8JEH02002)
 - DCPU F851 conduction check.
 - Replace DCPU. (Part# A795R73722)
 
L.3.10.3 (Link to the Field Service Manual)