CD3## (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD3##: Nonvolatile data error |
Rank | C |
Trouble detection condition | CD3##: Abnormality is detected by the abnormal check of each nonvolatile data. |
Trouble isolation | – |
Action

- Touch [Recover Data] displayed at the lower right portion on the trouble screen.
- A screen confirming whether to recover data appears.
- Select [Yes].
- The screen will be shifted to the data restoration screen to perform data restoration. NOTE: When the restoration is performed in a short time, data restoration screen may not be displayed.
- Check the message which indicates that the data restoration was successfully conducted. Turn OFF the main power switch and turn it ON again more than 10 seconds after. NOTE: In case it failed to restore data, return to the trouble code screen.
NOTE: Nonvolatile data backup will be automatically performed every hour. Backup can also be performed manually with the following setting. [Service Mode] -> [Enhanced Security] -> [Memory Data Backup]
L.3.18.24 (Link to the Field Service Manual)