C3421 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3421: Fusing warm-up trouble (Middle of the heating roller) |
Rank | A |
Trouble detection condition | Detected temperature of the thermistor/1 (TH1) or thermistor/2 (TH2) does not go up a given range of temperature even after a lapse of given period of time at warm up. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Thermistor/1 (TH1) -Thermistor/2 (TH2) -DC power supply (DCPU) -MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary.
- Check the connector between the fusing unit-relay CN7AC-DCPU CN2 for proper connection and correct as necessary.
- Check the connector between MFPB CN2E-DCPU CN7 for proper connection and correct as necessary.
- Replace the fusing unit. (Part# A7AHR72311 or A7AHPP3800(For refresh model))
- Replace MFPB. (Part# A7AHH0201D)
- Replace DCPU. (Part# A7AHR70500 or A7AHPP3300(For refresh model))
K.3.10.1 (Link to the Field Service Manual)