C7315 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7315: Fusing edge cooling fan/Fr failure |
Rank | B |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Fusing edge cooling fan/Fr (FM21) -Base board (BASEB) |
Procedure
- Check the connector between FM21-relay CN162-relay CN161-BASEB CN22E for proper connection and correct as necessary.
- Check the connector of FM21 for proper drive coupling and correct as necessary.
- FM21 conduction check.
- Control signal: BASEB CN22E-13 (REM), BASEB CN22E-15 (LOCK)
- Location of electrical component: 12-C
- Replace FM21. (Part# AA7NM10H00)
- Replace BASEB. (Part# ACV7H02101)