C0104 (C4751i)
Contents
Trouble type | C0104: Tray 3 drive motor malfunction (When PF-P27, PF-P28, PC-419, or PC-420 is installed) | |
Rank | B | |
Trouble detection condition | The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. | |
Trouble isolation | Tray 3/LCT | |
Relevant electrical parts | <When PF-P27 or PF-P28 is installed> | Tray 3 drive motor (M1/3)Tray 3 PC control board (PCCB/3)CPU board (CPUB)Base board (BASEB) |
<When PC-419 or PC-420 is installed> | LCT paper feed motor (M1)PC control board (PCCB)CPU board (CPUB)Base board (BASEB) |
Procedure
When PF-P27 or PF-P28 is installed
- Check the connector between M1/3-PCCB/3 CN4 for proper connection and correct as necessary.
- Check the connector between PCCB/3 CN1-relay CN2PC-PCCB/2 CN2 for proper connection and correct as necessary.
- Check the connector between PCCB/2 CN1-relay CN24-BASEB CN21E for proper connection and correct as necessary.
- Check the connector of M1/3 for proper drive coupling and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1/3 load check
- Check code: 28
- Multi code: 3, 4
- Control signal: PCCB/3 CN4-1 to 7
- Location of electrical component: 19-P
- Replace M1/3.
- PCCB/3 F1 and F2 conduction check
- Replace PCCB/3.
- Replace CPUB.
- Replace BASEB.
When PC-419 or PC-420 is installed
- Check the connector between M1-PCCB CN4 for proper connection and correct as necessary.
- Check the connector between PCCB CN1-relay CN24-BASEB CN21E for proper connection and correct as necessary.
- Check the connector of M1 for proper drive coupling and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1 load check
- Control signal: PCCB CN4-1 to 7
- Location of electrical component: 24-P
- Replace M1.
- PCCB F1 conduction check
- Replace PCCB.
- Replace CPUB.