Contents
| Trouble type | C7631: Supply power line 1 error |
| Rank | C |
| Trouble detection condition | All of the fuse detection units of the same supply power line (24V10) detected an error for a predetermined time. |
| Trouble isolation | – |
| Relevant electrical parts | DC power supply (DCPS)Base board (BASEB) |
Procedure
- BASEB F1E, F2E, F3E, F4E, F11E conduction check
- Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
- Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
- Replace DCPS.
- Replace BASEB.
(Link to the Field Service Manual)