Contents
Trouble type | C7633: Supply power line 3 error |
Rank | C |
Trouble detection condition | All of the fuse detection units of the same supply power line (24V20) detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | DC power supply (DCPS)Base board (BASEB) |
Procedure
- BASEB F8E, F18E, F19E conduction check
- Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
- Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
- Replace DCPS.
- Replace BASEB.
(Link to the Field Service Manual)