C0106 (bizhub 368/308)
Contents
Trouble type | C0106: Tray 3/transfer LCT paper feed motor turning at abnormal timing (When PC-110, PC-210, or PC-410 is installed) |
Rank | B |
Trouble detection condition | • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | <When PC-110 or PC-210 is installed> • Tray 3 paper feed motor (M111) • PC control board (PCCB) <When PC-410 is installed> • Paper feed motor (M131) • PC control board (PCCB) |
Procedure
When PC-110 or PC-210 is installed
- Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M111 for proper drive coupling and correct as necessary.
- M111 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-110/PC-210 4-C
- Replace M111. (Part# A2XMM10000)
- Replace PCCB. (PC-110/PC-210) (Part# A2XMH00101/Part# A2XMH00201)
NOTICE
When PC-410 is installed
- Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M131 for proper drive coupling and correct as necessary.
- M131 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-410 4-J
- Replace M131. (Part# A2XMM10000)
- Replace PCCB. (Part# A2XMH00301)
NOTICE
- Link to the wiring diagram (PC-410)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.7.2 (Link to the Field Service Manual)