C2414 (bizhub 368/308)
Contents
Trouble type | C2414: Developing unit/K new article release |
Rank | B |
Trouble detection condition | The status with the new unit is not cleared after the new developing unit is set. |
Trouble isolation | – |
Relevant electrical parts | • Developing unit • Front side board (FRB) • MFP board (MFPB) |
Procedure
- Reinstall developing unit.
- Check the connector between the developing unit-FRB CN13 for proper connection and correct as necessary.
- Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary.
- Replace the developing unit. (Part# A7U403D)
- Replace FRB. (Part# A9HJH00501)
- Replace MFPB. (Part# A9HJH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.10.2 (Link to the Field Service Manual)