C2564 (bizhub 368/308)

You are here:

Contents

Trouble typeC2564: Black TCR sensor failure
RankB
Trouble detection condition• Alarm signals for TCR sensor is detected more than the predetermined number of times.
• This detection is used for detecting disconnection of TCR sensor connector.
Trouble isolation
Relevant electrical parts• Developing unit
• Front side board (FRB)
• MFP board (MFPB)

 Procedure

  1. Reinstall developing unit.
  2. Check the connector between the developing unit-FRB CN13 for proper connection and correct as necessary.
  3. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary.
  4. Replace the developing unit. (Part# A7U403D)
  5. Replace FRB. (Part# A9HJH00501)
  6. MFPB ICP2E conduction check
  7. Replace MFPB. (Part# A9HJH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.6 (Link to the Field Service Manual)