92-40 (bizhub 558/458)

You are here:

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-40
JAM detection timingFor the second-side feed of paper in the duplex mode, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output.
Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts• ADU transport motor 2 (M26) 
• Registration sensor 1 (PS1) 
• Registration sensor 2 (PS72) (bizhub 558) 
• Expansion control board (EXCB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS1 I/O check, sensor checkEXCB CN6-3 (ON)26-P
3PS72 I/O check, sensor checkEXCB CN6-5 (ON)26-P
4M26 operation checkEXCB CN4-1 to 424-P
5Replace EXCB. (Part# A9HJH00501)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.18.1 (Link to the Field Service Manual)