C5360 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C5360: Clean unit fan failure to turn (When CU-102 is installed) |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Exhaust fan/1 (FM14) • Exhaust fan/2 (FM15) • Clean unit drive board (CUDB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between CUDB CN1-relay CN28D-BASEB CN28E for proper connection and correct as necessary.
- Check the connector between FM14-relay CN165-CUDB CN2, FM15-relay CN182-CUDB CN3 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM14 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
- Location of electrical component: 27-L
- FM15 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN3-1 (REM), CUDB CN3-3 (LOCK)
- Location of electrical component: 28-L
- Replace the defective fan. (FM14 / FM15) (Part # N/A, please contact Konica Minolta about replacement )
- Replace CUDB. (Not available in the U.S., please contact Konica Minolta about replacement)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.11.4 (Link to the Field Service Manual)