CE003 (958/808)
Contents
| Trouble type | CE003: Task error |
| Rank | C |
| Trouble detection condition | MFP board (MFPB) is faulty. |
| Trouble isolation | – |
| Relevant electrical parts | MFP board (MFPB) |
Procedure
- Check the connectors on MFPB for proper connection and correct as necessary.
- Replace MFPB. MFPB (Part# A796H02003)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.18.1. (Link to the Field Service Manual)