72-15 (bizhub 958/808)
Contents
JAM type | Misfeed at FS transport section | ||
JAM code | 72-15 | ||
JAM detection timing | <When FS-536 or FS-536SD is installed> The saddle exit sensor (PS5) is not turned OFF even after the set period of time has elapsed after it is turned ON. | ||
<When FS-537 or FS-537SD is installed> The SD discharge sensor (PS35) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. | |||
Misfeed processing location | Front door | ||
Relevant parts | <When FS-536 or FS-536SD is installed> • Saddle exit sensor (PS5) • FS control board (FSCB) | ||
<When FS-537 or FS-537SD is installed> • SD discharge sensor (PS35) • FS control board (FSCB) |
Procedure
When FS-536 or FS-536SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS5 I/O check, sensor check | FSCB J5-2 (ON) | FS-536/FS-536SD 16-K |
3 | Replace FSCB. (Part# A87GPP0V00) | – | – |
- Link to the wiring diagram (FS-536/FS-536SD)
When FS-537 or FS-537SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS35 I/O check, sensor check | FSCB J15-7 (ON) | FS-537/FS-537SD 15 to 16-K to L |
3 | Replace FSCB. (Part# A87HPP9M01) | – | – |
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.3 (Link to the Field Service Manual)