C2101 (bizhub 958/808)

You are here:

Contents

Trouble typeC2101: Charge cleaning motor/K malfunction
RankB
Trouble detection conditionDuring backward and return movement of the cleaner material, the charging cleaner home sensor (PS43) is not turned OFF (unblocked) after a predetermined period of time has elapsed.
Trouble isolation
Relevant electrical parts• Drum unit
• Charging cleaner home sensor (PS43)
• Charging cleaner return sensor (PS44)
• Charge cleaning motor/K (M15)
• PH relay board (PHRYB)
• MFP board (MFPB)

 Procedure

  1. Check the drum unit for proper connection and correct as necessary.
  2. Check the connector between M15-PHRYB CN4 for proper connection and correct as necessary.
  3. Check the connector of M15 for proper drive coupling and correct as necessary.
  4. Check the connector between PS43-PHRYB CN6 for proper connection and correct as necessary.
  5. Check the connector between PS44-PHRYB CN6 for proper connection and correct as necessary.
  6. PS43 I/O check, sensor check
    • Control signal: PHRYB CN6-5 (ON)
    • Location of electrical component: 3-B
  7. PS44 I/O check, sensor check
    • Control signal: PHRYB CN6-8 (ON)
    • Location of electrical component: 4-B
  8. M15 operation check
    • Control signal: PHRYB CN4-1 to 2
    • Location of electrical component: 5-B, 6-B
  9. Replace the drum unit. (Part# A8H40RD)
  10. Replace M15. (Part# A0P0R75200)
  11. PHRYB F2 conduction check.
  12. Replace PHRYB. (Part# A796H00300)
  13. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.1 (Link to the Field Service Manual)