C2356 (bizhub 958/808)
Contents
Trouble type | C2356: IU cooling fan/in’s failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • IU cooling fan /in (FM16) • MFP board (MFPB) |
Procedure
- Check the connector between FM16-relay CN700-MFPB CN18E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM16 operation check
- Control signal: MFPB CN18E-9 (DRIVE), MFPB CN18E-11 (LOCK)
- Location of electrical component: 15 to 16-K
- Replace FM16. (Part# 4556M10000)
- MFPB F7E conduction check
- Replace MFPB. (Part# A796H02003)
NOTICE
- Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.