C2650 (bizhub 958/808)
Contents
Trouble type | C2650: Main backup media access 1 error |
Rank | C |
Trouble detection condition | • The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • The main body detects that the back up board is not mounted. |
Trouble isolation | – |
Relevant electrical parts | Back up board/1 (ERB/1) |
Procedure
- Check the connector between ERB-MFPB CN5E for proper connection and correct as necessary.
- Replace MFPB. (Part# A796H02003)
- Replace ERB. (ERB/1 Part# A796H00C00)
- If the above actions do not solve the problem, contact KM.
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.8.17 (Link to the Field Service Manual)