17-20 (bizhub 958/808)
Contents
JAM type | Misfeed at LCT transport section (When LU-205 or LU303 is installed) | |
JAM code | 17-20 | |
JAM detection timing | The tray 2 vertical transport sensor (PS12) is not turned ON even after the set period of time has elapsed after the LU paper feed sensor (PS3) turns ON by a paper. | |
– | Paper jam of a sheet of paper left at the LCT transport section results, if the LU paper feed sensor (PS3) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. | |
Misfeed processing location | Lower right door | |
Relevant parts | • LU transport motor (M3) • LU paper feed sensor (PS3) • Tray 2 vertical transport sensor (PS12) • LU drive board (LUDB) • Paper feed/transport drive board (PFTDB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS3 I/O check, sensor check | LUDB CN5-8 (ON) | LU-205/LU-303 4-G |
3 | PS12 I/O check, sensor check | PFTDB CN12-10 (ON) | 3-P |
4 | M3 operation check | LUDB CN4-1 to 4 | LU-205/LU-303 3-G |
5 | Replace LUDB. (LU-205/LU-303)(Part# A8H6H00100) | – | – |
6 | PFTDB F1 or F4 conduction check | – | – |
7 | Replace PFTDB. (Part# A796H00200) | – | – |
- Link to the wiring diagram (LU-205)
- Link to the wiring diagram (LU-303)
- Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.6.7 (Link to the Field Service Manual)