C0105 (bizhub 958/808)

You are here:

Contents

Trouble typeC0105: Tray 3/4 feeder transportation motor’s turning at abnormal timing
RankB
Trouble detection condition The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolationTray 3 /4
Relevant electrical parts• LCC transport motor (M25) 
• Paper feed/transport drive board (PFTDB) 
• MFP board (MFPB)

 Procedure

  1. Check the connector between M25-PFTDB CN13 for proper connection and correct as necessary.
  2. Check the connector of M25 for proper drive coupling and correct as necessary.
  3. M25 operation check
    • Control signal: PFTDB CN13-1 to 7
    • Location of electrical component: 11-X
  4. Replace M25. (Part# A796M10001)
  5. PFTDB F15 conduction check
  6. Replace PFTDB. (Part# A796H00200)
  7. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.2 (Link to the Field Service Manual)