C0202 (bizhub C759/C659)
Contents
Trouble type | C0202: Tray 1 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 1 upper limit sensor (PS6) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 1 |
Relevant electrical parts | -Tray 1 upper limit sensor (PS6) -Tray 1 lift-up motor (M6) -Paper feed/transport drive board (PFTDB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M6-PFTDB CN25 for proper connection and correct as necessary.
- Check the connector of M6 for proper drive coupling and correct as necessary.
- Check the connector between PS6-relay CN145-PFTDB CN14 for proper connection and correct as necessary.
- PS6 I/O check, sensor check
- Control signal: PFTDB CN14-3 (ON)
- Location of electrical component: 1-P
- M6 load check
- Check code: 23
- Multi code: 4
- Control signal: PFTDB CN25-10 to 11
- Location of electrical component: 2-X
- Replace M6. (Part# A2X0M12001)
- PFTDB F10 conduction check
- Replace PFTDB. (Part# A795H00200)
L.3.7.3 (Link to the Field Service Manual)