C1141 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Paddle motor’s drive malfunction | |
Trouble code | C1141 | |
Rank | B | |
Detection timing | <When FS-534 is installed> The upper paddle homeposition detection sensor (PS14) is not blocked or unblocked even after the set period of time has elapsed while the FNS paddle motor (M5) is turning. | |
Trouble isolation | Staple | |
Relevant electrical parts | • FNS paddle motor (M5) • Upper paddle home position detection sensor (PS14) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M5-FSCB J4 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M5 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS14-FSCB J4 for proper connection, and correct as necessary. | – | – |
4 | PS14 I/O check, sensor check | FSCB J4<B>-7 (ON) | FS-534 13-C |
5 | M5 operation check | FSCB J4<A>-5 to 8 | FS-534 12-C to D |
6 | Replace M5 (Part# A3EPPP5500) | – | – |
7 | Replace FSCB(Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.26. C1141)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.14 (Link to the Field Service Manual)