How Can We Help?

C2151 (bizhub 754e/654e)

You are here:

Contents

Trouble type Secondary transfer roller pressure welding alienation
Trouble code C2151
Rank B
Detection timing• The 2nd transfer pressure sensor (PS50) doesn’t unblock (retracting) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is retracting.
• The 2nd transfer pressure sensor (PS50) doesn’t block (pressuring) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is pressuring.
Trouble isolation
Relevant electrical parts
• 2nd transfer pressure sensor (PS50)
• 2nd transfer pressure motor (M3)
• Paper feed/transport drive board (PFTDB)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M3-relay CN271B-PFTDB CN10 for proper connection and correct as necessary.
2 Check the connector of M3 for proper drive coupling and correct as necessary.
3 Check the connector between PS50-relay CN271A-PFTDB CN3 for proper connection and correct as necessary.
4 PS50 I/O check, sensor check PFTDB CN3-9 (ON) 5-P
5 M3 operation check PFTDB CN10-1 to 2 5-P
6 Replace M3 (Part# A0P0R75400 )
7 PFTDB ICP16 conduction check
8 Replace PFTDB (Part# A2X0H00202)
9 Replace PRCB (Part# A55VH00105)

Document Information ID D0001104758 Revise ID R000003