How Can We Help?

C2152 (bizhub 754e/654e)

You are here:

Contents

Trouble type Transfer belt pressure welding alienation
Trouble code C2152
Rank B
Detection timing• At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
• Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
Trouble isolation
Relevant electrical parts
• Transfer belt unit 1st transfer pressure sensor/K (PS51)
• 1st transfer pressure motor (M21)
• Printer control board (PRCB)
Operation Position Sensor status
Retraction -> Pressure Pressure ON (not blocked)
Pressure -> Retraction Retraction OFF (blocked)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M21-relay CN428-PRCB CN4 for proper connection and correct as necessary.
2 Check the connector of M21 for proper drive coupling and correct as necessary.
3 Check the transfer roller pressure gear of the transfer belt unit for proper engagement and the roller for rolling operation, and correct any faulty motion.
4 Check the connector between PS51-relay CN297-PRCB CN6 for proper connection and correct as necessary.
5 PS51 I/O check, sensor check PRCB CN6-1 (ON) 22-C
6 M21 operation check PRCB CN4-5 to 8 3 to 4-K
7 Replace M21 (Part# A02EM10C01)
8 Replace the transfer belt unit. (Part#
A55VR70000 )
9 PRCB ICP5 or ICP24 conduction check
10 Replace PRCBPRCB (Part# A55VH00105)

Document Information ID D0001104759 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.3 (Link to the Field Service Manual)