How Can We Help?

C6104 (bizhub 754e/654e)

You are here:

Contents

Trouble type Back side cleaning home sensor abnormality (initial)
Trouble code C6104
Rank B
Detection timing • The back side cleaning home sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
• The back side cleaning home sensor (PS9) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Trouble isolation Scanner
Relevant electrical parts • Back side cleaning home sensor (PS9)
• Back side cleaning motor (M7)
• DF control board (DFCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M7-relay CN119-DFCB CN6 for proper connection, and correct as necessary.
2 Check the connector of M7 for proper drive coupling, and correct as necessary.
3 PS9 I/O check, sensor check DFCB CN3-11 (ON) DF-702 6-C
4 M7 operation check DFCB CN6-5 to 8 DF-702 7-C
5 Replace M7M7 (Part# A0HUM10000)
6 DFCB ICP4 conduction check
7 Replace DFCBDFCB (Part# A3CKH00102)

Document Information ID D0001104805 Revise ID R000003