C6105 (bizhub 754e/654e)
Contents
Trouble type | Back side cleaning home sensor abnormality (normal) |
Trouble code | C6105 |
Rank | B |
Detection timing | At the time of operation other than the initial operation, the back side cleaning home sensor (PS9) error is detected. |
Trouble isolation | Scanner |
Relevant electrical parts | • Back side cleaning home sensor (PS9) • Back side cleaning motor (M7) • DF control board (DFCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M7-relay CN119-DFCB CN6 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M7 for proper drive coupling, and correct as necessary. | – | – |
3 | PS9 I/O check, sensor check | DFCB CN3-11 (ON) | DF-702 6-C |
4 | M7 operation check | DFCB CN6-5 to 8 | DF-702 7-C |
5 | Replace M7M7 (Part# A0HUM10000) | – | – |
6 | DFCB ICP4 conduction check | – | – |
7 | Replace DFCBDFCB (Part# A3CKH00102) | – | – |
- Link to the wiring diagram (N.1. bizhub 754e/654e)
- Link to the layout drawings for related parts by each trouble code (S.93. C6104, C6105)
Document Information ID D0001104805 Revise ID R000003