How Can We Help?

C6105 (bizhub 754e/654e)

You are here:

Contents

Trouble typeBack side cleaning home sensor abnormality (normal)
Trouble codeC6105
RankB
Detection timingAt the time of operation other than the initial operation, the back side cleaning home sensor (PS9) error is detected.
Trouble isolationScanner
Relevant electrical parts• Back side cleaning home sensor (PS9) 
• Back side cleaning motor (M7) 
• DF control board (DFCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M7-relay CN119-DFCB CN6 for proper connection, and correct as necessary.
2Check the connector of M7 for proper drive coupling, and correct as necessary.
3PS9 I/O check, sensor checkDFCB CN3-11 (ON)DF-702 6-C
4M7 operation checkDFCB CN6-5 to 8DF-702 7-C
5Replace M7M7 (Part# A0HUM10000)
6DFCB ICP4 conduction check
7Replace DFCBDFCB (Part# A3CKH00102)

Document Information ID D0001104805 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.