C9404 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCIS LED lighting abnormally
Trouble codeC9404
RankA
Detection timing<When DF-701 is installed>
After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Trouble isolationScanner
Relevant electrical parts-CIS module (CIS)
-CIS power supply (CISPU)
-Dual scan image processing board (DSIPB)
-MFP board (MFPB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection between CIS and DSIPB if faulty.
2Correct the harness connection between CIS and CISPU if faulty.
3Replace CIS (Part# A3CEM70000)
4CISPU F1, F2 conduction check
5Replace CISPU (Part# A3CEPP4Y00)
6Replace DSIPB (Part# A161H02A00)
7Replace MFPB (C364/C284 Part# A161H02104 / C224 Part# A4FMH02208)

K3.13.2 (Link to the Field Service Manual)