CD017 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD017: HDD mirroring error slave (rebuild) |
Rank | A |
Trouble detection condition | A R/W error occurs in the slave drive during HDD Mirroring Rebuild. |
Trouble isolation | – |
Relevant electrical parts | -Hard disk (A) (HDD (A)) -Hard disk (B) (HDD (B): HD-524) |
Procedure
- Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. If no problems are encountered, HDD Mirroring Rebuild is automatically performed.
- Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error. If an error occurs, “Error” appears in the status column.
- Replace the hard disk that has developed the error with a new one. (HDD (A) Part# A5C1M72H00 / HDD (B) Part# A2X0M72C00)
- Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [HDD Mirroring Rebuild] and perform the function.
L.3.18.9 (Link to the Field Service Manual)