C7320 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7320: IU cooling fan/in failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – IU cooling fan/in (FM16) – Base board (BASEB) |
Procedure
- Check the connector between FM16-relay CN700-BASEB CN18E for proper connection and correct as necessary.
- Check the connector of FM16 for proper drive coupling and correct as necessary.
- FM16 conduction check.
- Control signal: BASEB CN18E-7 (REM), BASEB CN18E-9 (LOCK)
- Location of electrical component: 14-K
- Replace FM16.
- Replace BASEB.