C0211 (bizhub 368/308)
Contents
Trouble type | C0211: Manual feed up/down abnormality |
Rank | B |
Trouble detection condition | • The bypass lift-up position sensor (PS26) is not turned OFF (unblock) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass lift-up position sensor (PS26) is not turned ON (blocked) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. |
Trouble isolation | Manual |
Relevant electrical parts | • Transport motor (M1) • Bypass pick-up solenoid (SD1) • Bypass lift-up position sensor (PS26) • MFP board (MFPB) |
Procedure
- Check the connector between M1-MFPB CN8E for proper connection and correct as necessary.
- Check the connector of M1 for proper drive coupling and correct as necessary.
- Check the connector between PS26-relay CN19-MFPB CN18E for proper connection and correct as necessary.
- Check the connector between SD1-relay CN21-relay CN19-MFPB CN18E for proper connection and correct as necessary.
- PS26 I/O check, sensor check
- Control signal: MFPB CN18E-13 (ON)
- Location of electrical component: 22-J
- SD1 operation check
- Control signal: MFPB CN18E-10 (ON)
- Location of electrical component: 22-J
- M1 operation check
- Control signal: MFPB CN8E-3 (REM), MFPB CN8E-6 (FGP)
- Location of electrical component: 2-C
- Replace M1. (Part# A7PUM10200)
- MFPB ICP3E conduction check
- Replace MFPB. (Part# A9HJH02102)
NOTICE
- Link to the wiring diagram (bizhub 368/308)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.7.11 (Link to the Field Service Manual)